Abstract

To establish the heterogeneity of hemodynamic responses to dobutamine in patients with septic shock and to identify the predictive factors of these hemodynamic responses. Prospective study. A total of 12 patients with septic shock in a tertiary medical intensive care unit. A 20-min dobutamine infusion at 5 microg.kg(-1).min(-1) with subsequent increments to 8, 12.6, and 20 microg.kg(-1).min(-1), on two consecutive days. Responses were dichotomized into changes in heart rate (HR) or stroke volume index (SVI) of >10% and < or =10% at the maximal dobutamine infusion. No differences were found in survival, Acute Physiology and Chronic Health Evaluation II score, maximal dobutamine doses, or pharmacokinetics of dobutamine between HR and SVI groups. In DeltaHR > 10% vs. DeltaHR < or = 10%, baseline HR was lower, and baseline mixed venous oxygen tension and saturation were higher. During dobutamine infusion, mean arterial pressure decreased in DeltaHR > 10%. Cardiac index and the systemic oxygen delivery index increased and the systemic vascular resistance index decreased at unchanged SVI. Pressure work index increased and the ratio of the diastolic to systolic aortic pressure time indices decreased but not to <0.6. In DeltaHR < or = 10%, systemic vascular resistance index and the ratio of the diastolic to systolic aortic pressure time indices decreased (but remained >0.6) without changes in SVI or cardiac index. Baseline hemodynamic and metabolic variables did not differ between SVI groups. In DeltaSVI > 10%, cardiac index increased with dobutamine, but Pao2 and the systemic oxygen delivery index decreased. In DeltaSVI < or = 10%, HR and the systemic oxygen delivery index increased; mean arterial pressure, left ventricular stroke work index, systemic vascular resistance index, and the ratio of the diastolic to systolic aortic pressure time indices decreased. Patients with a positive chronotropic response to dobutamine had lower baseline HR values, and a chronotropic rather than inotropic response predicted an increase in cardiac index and systemic oxygen delivery index. Incremental dosages of dobutamine did not compromise indirectly measured myocardial oxygen balance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.