Abstract

This work evaluated the hydrodynamic properties of heparin hydrolysed at temperatures ranging from 40 °C to 80 °C in buffered acid and alkaline environments. The correlation between hydrodynamic parameters led to the conclusion that polymer conformational changes appeared to be minimal until chain depolymerisation, initiated at pH 1 and 80 °C. However, the synergy of conformational changes, even if minimal, and sulphate loss observed at pH 1, pH 3 and pH 12 (various temperatures) resulted in a loss of the antifactor Xa activity. Therefore, the ‘contribution’ of conformational changes should be added to the generally recognized effect of desulphation towards the activity of heparin. This is of significance as the processing of medical heparin is complex, and requires adjustment of several physical and chemical factors, including pH and temperature.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call