Abstract
PurposeTo compare hemodynamic effects of two different modes of ventilation (volume-controlled and pressure-controlled volume guaranteed) in patients undergoing laparoscopic gynecology surgeries with exaggerated Trendelenburg position. MethodsThirty patients undergoing laparoscopic gynecology operations were ventilated using either volume-controlled (Group VC) or pressure-controlled volume guaranteed mode (Group PCVG) (n = 15 for both groups). Hemodynamic variables were measured using Pressure Recording Analytical Method by radial artery cannulation in addition to peak and mean airway pressures and expired tidal volume. ResultsThe only remarkable finding was a more stable cardiac index in Group PCVG, where other hemodynamic parameters were similar. Expired tidal volume increased in Group VC while peak airway pressure was lower in Group PCVG. ConclusionPCV-VG causes less hemodynamic perturbations as measured by Pressure Recording Analytical Method (PRAM) and allows better intraoperative hemodynamic control in exaggerated Trendelenburg position in laparoscopic surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Brazilian Journal of Anesthesiology (English edition)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.