Abstract

BackgroundThe number of patients with obesity undergoing various surgeries is increasing annually, and ventilation problems are highly prevalent in these patients.ObjectivesWe aimed to evaluate ventilation effectiveness with pressure-controlled (PC) and volume-controlled (VC) ventilation modes during laparoscopic bariatric surgery.MethodsIn this open-label randomized crossover clinical trial, 40 adult patients with morbid obesity candidates for laparoscopic bariatric surgery were assigned to VC-PC or PC-VC groups. Each patient received both ventilation modes sequentially for 15 min during laparoscopic surgery in a random sequence. Every 5 min, exhaled tidal volume, peak and mean airway pressure, oxygen saturation, heart rate, mean arterial pressure, and end-tidal CO2 were recorded. Blood gas analysis was done at the end of 15 min. Dynamic compliance, PaO2/FiO2 ratio, P (A-a) O2 gradient, respiratory dead space, and PaCO2-ETCO2 gradient were calculated according to the obtained results.ResultsThe study included 40 patients with a mean age of 35.13 ± 9.06 years. There were no significant differences in peak and mean airway pressure, dynamic compliance, and hemodynamic parameters (P > 0.05). There was no significant difference between the two ventilation modes in pH, PaCO2, PaO2, PaO2/FIO2, dead space volume, and D (A-a) O2 at different time intervals (P > 0.05).ConclusionsIf low tidal volumes are used during adult laparoscopic bariatric surgery, mechanical ventilation with PC mode is not superior to VC mode.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call