Abstract

Korea has the world's most strict inter-floor noise regulations. In order to build an apartment house with more than 30 units, it must meet the minimum requirement of impact sound level, single number quantities of 49 dB. These regulations make it hard to expand residential tall wood building in Korea. For making quality satisfied CLT floors, as the preliminary investigations, the effects of wood species and CLT panel joints on the vibration and sound insulation performance of CLT were analyzed. The natural frequency range of the CLT slabs is from 20 Hz to 22 Hz. There were no significant differences depending on wood species and CLT panel joint type. As the stiffness of the slabs increased, the floor impact sound insulation performance also improved. The deflection model for CLT slabs was developed and validated with the actual deflection derived by acceleration spectrum. The measured value was 62 ~ 87% of the predicted value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.