Abstract

Long-term behaviour is a major issue related to the use of zero-valent iron (ZVI) in permeable reactive barriers for groundwater remediation; in fact, in several published cases the hydraulic conductivity and removal efficiency were progressively reduced during operation, potentially compromising the functionality of the barrier. To solve this problem, the use of granular mixtures of ZVI and natural pumice has recently been proposed. This paper reports the results of column tests using aqueous nickel and copper solutions of various concentrations. Three configurations of reactive material (ZVI only, granular mixture of ZVI and pumice, and pumice and ZVI in series) are discussed. The results clearly demonstrate that iron-pumice granular mixtures perform well both in terms of contaminant removal and in maintaining the long-term hydraulic conductivity. Comparison with previous reports concerning copper removal by ZVI/sand mixtures reveals higher performance in the case of ZVI/pumice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.