Abstract

Over a range of 70 < Rea < 9600, 7 < Pra < 130, 0 < ∃ < 0.12 and 0.7 < n < 1, circumferential wall temperatures for air-water and air-aqueous polymer (viscoelastic) solution flows over a horizontal cylinder were measured experimentally. The 2.5-cm-diameter and 7.5-cm-length cylinder was heated by passing direct electric current through it. The peripherally averaged heat transfer coefficient for relatively dilute viscoelastic-air solutions, at any fixed flow rate of liquid phase, increases with ∃. Such increase is more pronounced at lower flow rates of liquid phase. For relatively more elastic solutions, the two-phase heat transfer decreases with increasing ∃. Such reduction is more pronounced at higher flow rates of liquid phase. A new correlation is proposed for predicting the Nusselt number for air-viscoelastic fluid flows over a heated cylinder in cross flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.