Abstract

Heat load studies have been performed for the first crystal of a double crystal monochromator to be installed in a beamline of the 2·5 GeV synchrotron radiation source Indus-2. Finite element analysis (FEA) has been used to calculate the temperature distribution and the mechanical distortions on these crystals. Several cases of cooling schemes and heat loads have been studied. Based on these FEA results, the analytical relationships available in the literature have been modified. It is shown that modified analytical results compare well with the empirical results obtained from FEA. The optimisation of the cooling conditions can be achieved by doing FEA calculations for only one case. All other cases can then be calculated by using analytical relations proposed here. The proposed analytical equations are generic in nature and can be applied for any source—crystal combination and therefore would be useful for performance prediction of any new monochromator on a new synchrotron source without taking recourse to time consuming, computation-intensive FEA.