Abstract

The condensation process of steam inside horizontal tubes during natural circulation gains in importance regarding the reactor safety research for existing and future nuclear power plants. Experimental investigations due to the condensation process were realized with the rig HORUS to study the behaviour of water-steam-gas mixtures in horizontal tubes. The paper includes statements regarding the flow and heat transfer conditions inside the tube and the temperature distribution inside the small tube wall. The experiments showed a blockade of the heat transfer area with Nitrogen which is connected with an increasing primary pressure followed by a compression of the Nitrogen and a reentry of steam into the tube. The experiments serve for the creation of an experimental data base. A model development for calculation of the heat transfer is described. The model was implemented in the German thermal-hydraulic code ATHLET. The comparison of calculated data and the measured parameters of HORUS rig show the code improvement for the simulation of noncondensing gases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.