Abstract

This paper presents some experimental data about evaporating heat transfer in horizontal tubes about 4.75mm I.D. with small internal spiral grooves using R efrigerant R12. The groove inclinations of the tested internal spiral-grooved tubes are 4, 7, 15 and 30 degrees. It is found that a spiral-grooved tube can increase the evaporating heat transfer coefficient in tubes from one and a half times to twice as much as that of a smooth tube for annular flow region, and about ten times due to capillary phenomenon in grooves for stratified flow region.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.