Abstract
This paper presents some experimental data about evaporating heat transfer in horizontal tubes about 4.75mm I.D. with small internal spiral grooves using R efrigerant R12. The groove inclinations of the tested internal spiral-grooved tubes are 4, 7, 15 and 30 degrees. It is found that a spiral-grooved tube can increase the evaporating heat transfer coefficient in tubes from one and a half times to twice as much as that of a smooth tube for annular flow region, and about ten times due to capillary phenomenon in grooves for stratified flow region.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.