Abstract
The present study introduced a novel chaotic coil heat exchanger utilizing chaotic advection to enhance heat transfer at low Reynolds numbers. Using Lagrangian tracing of fluid particles and their sensitivity to the initial condition and fluid element calculations, it was shown that mixing was significantly increased due to the chaotic advection. Heat transfer performance in the coil and chaotic configuration was visualized by isotherms contours of temperature in different cross-sections. In order to evaluate the hydraulic-thermal performance of heat exchangers, Nusselt numbers and friction factor were calculated and comparison was made between the two configurations. Numerical calculations revealed that the chaotic coil configuration displayed heat transfer enhancement of 4–26% relative to the fully developed Nusselt numbers in the regular coil with only 5–8% change in the pressure drop.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.