Abstract

The present study examines the augmentation in heat transfer and friction in a flow through heat exchanger tube with multiple square perforated twisted tape inserts. The experimental outcomes pertaining to Reynolds number (Ren) from 5000 to 27000, perforation width ratio (a/WT) from 0.083-0.333 and twist ratio (TL/WT) from 2.0-3.5 have been presented and discussed. Multiple square perforated twist tape brought out considerable enhancement in heat transfer rates over without square perforated multiple twisted tape and plain tube. The maximum enhancement is observed at a a/WT of 0.250 and TL/WTof 2.5. Correlations of Nusselt number, friction factor and thermal hydraulic performance are established in term of Reynolds number and geometrical parameter of twisted tape which can be used to predict the values of Nusselt number, friction factor and thermal hydraulic performance with considerably good accuracy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.