Abstract

An experimental study of enhancement of heat transfer due to V-shaped perforated blockages attached to the heated surface has been presented in this paper. The duct equipped with perforated V-blocks had an aspect ratio (W/H) of 12, relative blockage height ratio (e/H) of 0.8, angle of attack (α) of 60° and open area ratio (β) of 20%, while relative pitch ratio (P/e) was varied from 4 to 12. The values of Nusselt number and friction factor of the duct with blockages were compared with values of Nusselt number and friction factor of the smooth duct operating under similar experimental conditions. It was found that there was a significant effect on the Nusselt number ratio and friction factor ratio when the pitch ratio was changed and there was exist an optimum value of pitch ratio. Thermal hydraulic performance was found to be maximum corresponding to relative pitch value of 8.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call