Abstract

The heat capacities of unirradiated silica glass and three samples of fast neutron-irradiated silica glass were measured between 6 and 340 K. For the glass samples irradiated with fast neutrons, a decrease in heat capacity was observed in comparison with the starting silica glass. This agrees with the assumption that at higher doses the silica glass is converted into the metamict phase, which has a different local structure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.