Abstract

The mechanism of human thermal comfort is important for building a comfortable and healthy indoor environment. This paper analyzes human heart rate variability (HRV) at different thermal comfort levels and discusses the mechanism of human thermal comfort. A total of 33 subjects were divided in 3 groups. Under air temperatures of 21, 24, 26, 28, 29, and 30 degrees C, the subjects' electrocardiogram was recorded for 5 min. HRV (the ratio of absolute powers in low- and high-frequency bands, LF/HF ratio) was analyzed. LF/HF at discomfort level were significantly higher than that at comfort level (P < 0.05), despite the same thermal sensation. The results indicate that sympathetic activity plays an important role in subjects' thermal discomfort and the LF/HF ratio may be used as an indicator for human thermal comfort.