Abstract
Background and purposeCardiac disease has been related to heart dose after left-sided breast radiotherapy. This trial evaluates the heart sparing ability and feasibility of deep inspiration breath hold (DIBH) in the prone position for left-sided whole breast irradiation (WBI). Materials and methodsTwelve patients underwent CT-simulation in supine shallow breathing (SB), supine DIBH, prone SB and prone DIBH. A validation cohort of 38 patients received prone SB and prone DIBH CT-scans; the last 30 patients were accepted for prone DIBH treatment. WBI was planned with a prescription dose of 40.05Gy. ResultsDIBH was able to reduce (p<0.001) heart dose in both positions, with results for prone DIBH at least as favorable as for supine DIBH. Mean heart dose was lowered from 2.2Gy for prone SB to 1.3Gy for prone DIBH (p<0.001), while preserving the lung sparing ability of prone positioning. Moreover prone DIBH nearly consistently reduced mean heart dose to less then 2Gy, regardless of breast volume. All patients were able to perform the simulation procedure, 28/30 patients were treated with prone DIBH. ConclusionsThis trial demonstrates the ability and feasibility of prone DIBH to acquire optimal heart and lung sparing for left-sided WBI.
Published Version (
Free)