Abstract
This study presents general winding power loss expressions for a high-frequency (HF) three-winding forward transformer operated in continuous conduction mode (CCM), where the source of the transformer excitation is considered to be non-sinusoidal with many significant harmonics. The efficient operation of an isolated converter is dependent upon the performance of the transformer used. The expressions presented in this study take into account the eddy-current losses caused by current harmonics at HFs. The expressions are derived based on Fourier series of the winding current waveforms, and using Dowell's equation, which considers both the skin and proximity effects caused by eddy currents. Harmonic winding loss factors for the three windings are introduced. In addition to the power loss expressions, a step-by-step procedure to design a three-winding transformer used in a single-switch forward converter operated in CCM is presented using the area product (Ap) method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.