Abstract

Problems with corrosion of prestressing steel in post-tensioned structures due to inadequate grouting have become more apparent in recent years. To improve grouting practices, a series of fresh property tests, accelerated corrosion tests, simulated field tests, and long-term corrosion tests were used in this study to develop optimum grouts for post-tensioning. Grouts possessing adequate workability and bleed resistance were tested in an accelerated corrosion test to evaluate relative corrosion protection properties. This paper focuses on the accelerated corrosion test results. The most promising of these grouts were then tested for placeability under simulated field conditions. A fly ash grout and a thixotropic grout are recommended from this testing program. Fluidity, bleed, and corrosion resistance data was also acquired for a number of different combinations of pozzolans and admixtures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.