Abstract

This paper presents a grid-connected control strategy for single-phase photovoltaic (PV) system. Voltage source inverter (VSI) of a PV system is a core component which will produce some harmonics when the switch is operated between on and off continuously. To suppress harmonic distortion in the VSI output current, a fixed modulation index (MI) control loop based on PI controller is added to the traditional double closed-loop. The proposed method can fix the MI coefficient to be a large value in any conditions. The design of the controller and the stability of the grid-connected system are discussed in detail. Simulation and experiment results are presented to demonstrate the dynamic and precision performance of the controller for harmonic suppression when the proposed PV system is connected to the grid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.