Abstract
A convenient and environmentally friendly method of fabricating glucose biosensors is proposed. Glucose oxidase (GOD) was immobilized on electrochemically reduced graphene oxide (ERGO) which was adsorbed on the poly-L-lysine (PLL) modified glassy carbon electrode after being immersed in GO solution for 4 h. The electrochemical behaviors of GOD/ERGO/PLL/GC electrode have been investigated by cyclic voltammetry. Direct electron transfer between GOD immobilized with ERGO/PLL and GC electrode was observed. Moreover, the GOD/ERGO/PLL/GC electrode exhibited excellent electrocatalytic activity for the detection of glucose with a linear range from 0.25 to 5 mmol L(-1).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.