Abstract
The initiation of streamers prior to a lightning strike can be reportedly inhibited by glow corona discharges generated from tall objects. In contrast to previous studies based on a simplified one-dimensional model of glow corona, a two-dimensional evaluation of the corona ion drift from tall objects is used here to analyse this effect quantitatively. Proper estimates for the corona space charge distribution generated during both the charging process of a thundercloud and the descent of the downward stepped leader are thus calculated. It is found that the shielding effect of the corona space charge on the streamer inception is not as severe as previously reported. Estimations of the effective height of the downward leader tip at which streamer inception takes place are presented and discussed for lightning rods and dissipation array systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.