Gillies' corner stitch (GCS) has been generally accepted for closure of skin flap tips because it is commonly believed that this stitch provides the best chance for survival of a flap tip that may have a compromised blood supply. There are no experimental data, however, to support such an assumption. To test the hypothesis that other stitches might be equally efficacious, we evaluated flap tip survival after closure with two different suture techniques, the GCS and a vertical loop stitch ( VLS ). Factors used to evaluate flap tip viability were the measurement of RBC movement in the flap tip by laser Doppler technique and measurement of the length of flap tip necrosis. In our model, the GCS is not superior to the VLS in terms of flap tip survival.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.