Abstract

Abstract The effect of geometric parameter on laminar mixed convection in the entrance region of shrouded arrays of heated rectangular blocks is approached numerically for large Prandtl number fluid. The problem considered is related to convective cooling of electronic components mounted on horizontal circuit boards. Typical development of streamline and isotherm, block wall temperature distribution, and local Nusselt number are presented. It is found that the secondary flow leads to a significant enhancement in heat transfer. The multiple eddies above the block, induced by the combined geometric and buoyancy effect, lead to a more uniform block wall temperature distribution and then reduce the magnitude of the highest wall temperature.