Abstract

Abstract : An evaluation of the geological seismological hazard was conducted at the St. Stephen Powerhouse Project, which is part of the cooper River Rediversion Project in South Carolina. The project is located about 60 km North of Charleston, SC, and consists of a reinforced concrete powerhouse structure founded on rock, flanked by rolled fill earth embankments, founded partially on rock and partially on alluvium. For the purposes of this study, the alluvium is assumed to be competent, not susceptible to liquefaction. The Maximum Credible Earthquake (MCE) is estimated to correspond to a magnitude 7.5 event, 55 km from the site, resulting in peak ground accelerations at the site of 0.32 and 0.35 g. The Operating Basis Earthquake (OBE) is estimated to correspond to about a magnitude 5 event, resulting in a peak ground acceleration of 0.04 to 0.05 g at the site. The Newmark sliding block analyses indicate deformations in the maximum section under the MCE will be negligible, less than 1 cm. However, deformation under retaining walls and embankments founded on natural ground may be on the order of 15 to 35 cm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.