Abstract

With the standstill frequency-response (SSFR) test, accurate electrical-machine models can be identified. However, it can be a time-consuming method, particularly in case the machine has to be identified at low frequencies. To shorten the required time for identification, in this paper, the response on a broadband signal is measured, resulting in a multisine SSFR test. To generate the broadband signal, a high-power linear amplifier can be applied as a waveform generator. As this signal generator is not commonly available in the field, the application of a voltage-source inverter (VSI) is discussed. The multisine SSFR test with a VSI allows swift evaluation of the influence of frequency, saturation, and cross saturation on the q-and d-axis parameters with a signal generator that is often already available to control the machine. Extensive measurements are performed on several permanent-magnet synchronous machines and the method can be extended to synchronous machines with rotor-field winding. By applying a switching converter instead of a linear amplifier, it can be expected that the identification results are affected by the switching actions. Therefore, multisine SSFR tests with either a VSI or a high-power linear amplifier as well as conventional tests as described in the IEEE standard are performed, and the results are compared.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call