Abstract

A three transfer functions approach for the standstill frequency response (SSFR) test of synchronous machines is proposed. Network theory is employed for the explanation of the three-function approach. The three-function and two-function approaches, as well as the one-function approach, are compared. The verification of the approach is obtained through simulations and an application to an SSFR test on a 3 kVA laboratory microalternator. The accuracy of the determined d-axis model parameters, particularly of the rotor circuits, is improved by the use of the suggested third transfer function (L/sub afo/(s)) together with the two transfer functions (L/sub d/(s) and G(s)). This requires that the measurements of the three transfer functions be taken in the SSFR test and be involved in the d-axis model fitting instead of the common practice involving only L/sub d/(s) and G(s). >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.