Abstract

Power devices are susceptible to failure by terrestrial neutron single-event burnout (SEB) while in the high-voltage blocking state and above a VDS threshold for that device. Typically, the SEB failure rate is measured at a high blocking voltage, with the source and gate at ground potential. Here the effect of a negative gate bias, commonly applied during MOSFET switching to the blocking state, on the SEB failure rate is examined. It is observed that the SEB failure rate is only weakly dependent on the negative gate bias, because it does not significantly affect the peak field in the drift region where avalanche breakdown is initiated. A negative gate bias of -8VGS in the device blocking state at 1100VDS only results in a 6% increase in the MOSFET SEB failure rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.