Abstract

We report an experimental study of the performance parameters of a gas discharge pumped thallium vapour laser operating on the 7s2S1/2 - 6p2P3/2o self-terminating transition at 535 nm. The switch we used, a TPI3-10k/25 cold-cathode thyratron, ensures a rise time of the load voltage pulse less than 15 ns. The laser output power is shown to increase in proportion to the energy stored in the discharge capacitor (up to the maximum voltage of the thyratron). The optimal pump pulse repetition rate for He(Ne)—Tl mixtures is ∼1.75 kHz. Even small hydrogen additions reduce the lasing energy and average output power. The addition of bismuth vapour increases the optimal pulse repetition rate (up to 3 kHz) and average output power. The factors responsible for the lower lasing efficiency in comparison with the copper vapour laser are analysed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.