AbstractGaN‐based p–i–n X‐ray detectors have been fabricated. We observed using SEM that the surface of a GaN sample has a large number of hexagonal defects. The SEM results show that GaN itself contains numerous screw dislocations that will be the flow channel of leakage current, which in turn increased the reverse‐bias leakage current of detectors. We have observed a two‐step increase in X‐ray photocurrent, which is caused by two different detection mechanisms: photovoltaic and photoconductive, and the total photocurrent (Jp) to dark current (Jd) ratio is about 27.7 times and the net photocurrent is about 2.52 µA at 110 V reverse bias. As the X‐ray accelerating voltage increases, the photocurrent has a sublinear trend.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.