Abstract

ELI-NP-GBS is a high-brilliance gamma source that will produce monochromatic beams in the energy range 0.2–19.5 MeV through inverse Compton scattering . In order to obtain a monochromatic beam a collimation of the emission is necessary. Depending on the energy, the angular aperture required to provide the design bandwidth Δ E/E=0.5% is between 70 and 700 μ rad. This collimation is provided by a stack of 14 tungsten slits, arranged with a relative rotation around the beam axis, so that the overlap will be a continuously adjustable aperture. To monitor the operation and alignment of the collimation, a set of detectors will provide a complete characterization of the gamma beam, including the measurement of the transverse spatial distribution. For this task a gamma beam profile imager based on a thin scintillator screen and a high-resolution CCD-camera was developed. In this work we briefly present the status of the collimation system and beam profile imager, which were designed, assembled and are currently under test at INFN-Ferrara laboratories.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.