Abstract

The receiver system is an essential part of the solar tower power plant and it is important for stable power generation. This paper introduces a molten salt receiver system model and discusses structure selection of the cold surge tank under this model. It seems the structure of cold surge tank has little effect on system performance. A system simulation is used to create emergency conditions in order to directly demonstrate the function of the cold and hot surge tanks. The results show the necessity of both tanks. Cold surge tank can effectively improve the safety of receiver during pump failure while hot surge tank can greatly increase the operation time during downcomer blockage. The outlet temperature and level control failure are also analyzed. The results demonstrate the possible consequences of a control system failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.