Abstract

A free-space method is in wide spread use for the reflectivity measurement of electromagnetic wave absorbers (EMA) in VHF and UHF range. In the free-space method, the reflection levels from EMA and from the metal plate with same size as the EMA are measured, and the reflectivity is calculated from their ratio. The incident angle such as normal or oblique must be defined, and the polarization of electromagnetic (EM) wave must be specified to be TE, TM, or circularly-polarized mode. In this paper, a parallel EM wave beam method using dielectric lenses in front of horn antennas was studied experimentally. Electromagnetic wave absorption was measured with the vertical and the oblique incidence by using this parallel EM wave beam. This measurement system has following features: • It is compact because equiphase parallel EM wave beam was obtained in a short distance from the dielectric lens. • It requires no anechoic chamber because of little multi-reflection due to high directivity of parallel EM wave beam. • It allows a large oblique incident measurement by using high directive parallel EM wave beam.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.