Abstract

BackgroundThe potential of diesel soot aerosol particles to break up into smaller units under mechanical stress was investigated by a direct impaction technique which measures the degree of fragmentation of individual agglomerates vs. impact energy. Diesel aerosol was generated by an idling diesel engine used for passenger vehicles. Both the aerosol emitted directly and aerosol that had undergone additional growth by Brownian coagulation ("aging") was investigated. Optionally a thermo-desoption technique at 280°C was used to remove all high-volatility and the majority of low-volatility HC adsorbates from the aerosol before aging.ResultsIt was found that the primary soot agglomerates emitted directly from the engine could not be fragmented at all. Soot agglomerates permitted to grow additionally by Brownian coagulation of the primary emitted particles could be fragmented to a maximum of 75% and 60% respectively, depending on whether adsorbates were removed from their surface prior to aging or not. At most, these aged agglomerates could be broken down to roughly the size of the agglomerates from the primary emission. The energy required for a 50% fragmentation probability of all bonds within an agglomerate was reduced by roughly a factor of 2 when aging "dry" agglomerates. Average bond energies derived from the data were 0.52*10-16 and 1.2*10-16 J, respectively. This is about 2 orders of magnitude higher than estimates for pure van-der-Waals agglomerates, but agrees quite well with other observations.ConclusionAlthough direct conclusions regarding the behavior of inhaled diesel aerosol in contact with body fluids cannot be drawn from such measurements, the results imply that highly agglomerated soot aerosol particles are unlikely to break up into units smaller than roughly the size distribution emitted as tail pipe soot.

Highlights

  • Diesel soot aerosol particles are usually agglomerated to varying degrees, depending on whether they have freshly emerged from the tailpipe, or whether they are aged as in the case of prolonged residence times in a street tunnel

  • In conjunction with the assessment of health risks posed by inhaled diesel soot in contact with tissue and body fluids, the potential for breaking up larger agglomerate structures into smaller units may have various implications, as well

  • We present exploratory results obtained with the above mentioned technique on the fragmentability of soot aerosol particles produced by a passenger vehicle diesel engine, and on the effect of an exhaust after-treatment on the agglomerate strength

Read more

Summary

Results

It was found that the primary soot agglomerates emitted directly from the engine could not be fragmented at all. Soot agglomerates permitted to grow by Brownian coagulation of the primary emitted particles could be fragmented to a maximum of 75% and 60% respectively, depending on whether adsorbates were removed from their surface prior to aging or not. At most, these aged agglomerates could be broken down to roughly the size of the agglomerates from the primary emission. Average bond energies derived from the data were 0.52*10-16 and 1.2*10-16 J, respectively This is about 2 orders of magnitude higher than estimates for pure van-der-Waals agglomerates, but agrees quite well with other observations

Conclusion
Introduction
Results and discussion
Summary and conclusion