Abstract
The purpose of this study was to analyse the involvement of the gliding surface of the biceps tendon in fractures of the proximal humerus. Fifteen patients had a fracture of the proximal humerus verified with antero-posterior and axillary radiographs. Tangential radiographs of the intertubercular groove, obtained from the shoulder joint, showed involvement of the intertubercular groove in 13 patients (87%), which could not be shown with other projections. Groove radiographs revealed in 3 patients a dislocation of the fragments of the greater tuberosity large enough to require surgical treatment, but which had not been found using conventional techniques. Therefore, a groove radiograph should be used to precise fractures of the proximal humerus.