Abstract
The fracture toughness of a crystalline silicon carbide fiber, Tyranno‐SA®, was determined by introducing an artificial notch directly into the fiber test specimens using a focused‐ion (Ga+) beam. The relation between fracture strength and notch size was determined experimentally, while the relation among the notch size, fiber diameter, applied stress at infinity, and stress intensity factor was analyzed by the finite element method. By applying the analyzed result to the experimental results, the fracture toughness of the fiber was determined to be .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.