Abstract

The Mixed-Mode Controlled Double Cantilever Beam (MC-DCB) test has been developed to test samples under mixed-mode loading in a combination of mode I and mode III. The mixed-mode ratio is defined based on J-integral and the principle of superimposition holds even in the case of nonlinear fracture behavior. This mixed-mode ratio is externally controlled to be constant during the entire test duration by realizing the MC-DCB test setup as a dual-actuator test in a biaxial testing machine.In this work, test results at constant mode-mixity on two different kinds of adhesive joints are presented: elastic-plastic adhesive joints made of SikaPower®-498 and rather brittle adhesive joints made of Henkel Teroson® EP4510GB. These recently achieved test results give more detailed information on the fracture behavior of the particular adhesive joints. With regard to cohesive zone modelling of possible joint failure, the traction-separation behavior at the initial crack tip has been evaluated by considering the crack-tip opening displacement, which has been measured by digital image correlation in the experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.