Abstract
The Kovar alloy leads broke from two integrated circuits (ICs) with TO (Tin Outline) package. Through the metallurgical microstructure analysis, energy dispersive spectrometer (EDS) analysis and fractography analysis, the failure mode of the leads was found to be stress-corrosion-cracking. After checking the whole plating process, it was found that the residual chloride ions resulted in stress-corrosion-cracking. The chloride ions were absorbed inside the residual organic containment below Ni-plating layer. And a corrective measure was proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.