Abstract
ObjectivesThe study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).BackgroundDiscordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels.MethodsBaseline and hyperemic coronary flow velocity and coronary flow reserve (CFR) were compared across 5 vessel groups: FFR+/iFR+ (108 vessels, n = 91), FFR–/iFR+ (28 vessels, n = 24), FFR+/iFR– (22 vessels, n = 22), FFR–/iFR– (208 vessels, n = 154), and an unobstructed vessel group (201 vessels, n = 153), in a post hoc analysis of the largest combined pressure and Doppler flow velocity registry (IDEAL [Iberian-Dutch-English] collaborators study).ResultsFFR disagreed with iFR in 14% (50 of 366). Baseline flow velocity was similar across all 5 vessel groups, including the unobstructed vessel group (p = 0.34 for variance). In FFR+/iFR– discordants, hyperemic flow velocity and CFR were similar to both FFR–/iFR– and unobstructed groups; 37.6 (interquartile range [IQR]: 26.1 to 50.4) cm/s vs. 40.0 [IQR: 29.7 to 52.3] cm/s and 42.2 [IQR: 33.8 to 53.2] cm/s and CFR 2.36 [IQR: 1.93 to 2.81] vs. 2.41 [IQR: 1.84 to 2.94] and 2.50 [IQR: 2.11 to 3.17], respectively (p > 0.05 for all). In FFR–/iFR+ discordants, hyperemic flow velocity, and CFR were similar to the FFR+/iFR+ group; 28.2 (IQR: 20.5 to 39.7) cm/s versus 23.5 (IQR: 16.4 to 34.9) cm/s and CFR 1.44 (IQR: 1.29 to 1.85) versus 1.39 (IQR: 1.06 to 1.88), respectively (p > 0.05 for all).ConclusionsFFR/iFR disagreement was explained by differences in hyperemic coronary flow velocity. Furthermore, coronary stenoses classified as FFR+/iFR– demonstrated similar coronary flow characteristics to angiographically unobstructed vessels.
Highlights
Discordance between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) occurs in up to 20% of cases
An analysis of only 1 vessel per patient does not reflect real-world experience, where treating physicians make revascularization decisions on the vessel rather than patient level. In this analysis to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by FFR and iFR, discordance could be rationalized by differences in hyperemic coronary flow velocity, coronary flow reserve (CFR) and the prevalence of diabetes
In comparison to FFR–/iFRþ discordant cases, FFRþ/iFR– discordant cases were associated with higher hyperemic coronary flow velocity and CFR, and a lower prevalence of diabetes
Summary
The study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR)
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have