Abstract

The aim of this study was to determine the prognostic significance of nonlinear and standard heart rate (HR) variability parameters in predicting future adverse events (AEs) in patients with implantable cardioverter-defibrillators. In postinfarction studies, nonlinear measures of HR variability obtained from long-term electrocardiographic recordings have been suggested to be better predictors of adverse outcomes than conventional HR variability measures. Fifty-five high-risk patients with reduced left ventricular function and an implantable cardioverter-defibrillator had a 10-minute, high-resolution electrocardiographic recording after which they were followed for 25 months on average. Implantable cardioverter-defibrillator shock or death was determined as the end point. The SD of all normal-to-normal RR intervals, the square root of the mean squared differences of successive normal-to-normal RR intervals, and the proportion of interval differences of successive normal-to-normal RR intervals >50 ms, low-frequency and high-frequency powers of the power spectrum and their ratio were calculated as conventional measures of HR variability. The short-term scaling exponent (α 1) and approximate entropy were determined as nonlinear measures of HR variability. AEs occurred in 23 patients (42%). Patients with AEs had significantly lower α 1 than event-free patients: 0.81 ± 0.29 (mean ± SD) versus 1.01 ± 0.30 (p = 0.02). None of the other HR variability parameters differed significantly between patients with and without AEs. In the Cox proportional-hazards model including age, gender, ejection fraction, occurrence of ventricular tachyarrhythmia before defibrillator implantation, β-blocker usage, and α 1, only α 1 was an independent predictor of AEs: hazard ratio 1.20 (95% confidence interval 1.03 to 1.39) for every 0.10 decrease in α 1 (p = 0.020). In conclusion, α 1 obtained from a 10-minute electrocardiographic recording yields important prognostic information about the risk of AEs in patients with implantable cardioverter-defibrillators.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.