In this paper, a new ZVT forward converter is presented in which the third winding of the forward converter is utilised to transfer power from the input to the output, recover the energy of the leakage inductance and snubber capacitance, and also provide ZVS condition for the converter switch. In the proposed converter, the main switch is turned ON and OFF under ZVS condition, and the auxiliary switch operates under ZCS condition. Besides, all the diodes are turned OFF under ZCS condition, and their reverse recovery losses are alleviated. Moreover, in the proposed converter, the voltage stress of the auxiliary switch is limited to the input voltage. As a result, the efficiency is improved. Since both converter switches and the input voltage share the same ground, no isolated gate driver is required in the implementation of the introduced converter. Also, due to the almost flat efficiency curve of the proposed converter, it is suitable for applications where the load range is wide. The proposed converter analysis, operating principals and design considerations are discussed in this paper, and the converter performance is justified by the implementation results from a 240 W prototype converter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.