Abstract
This study presents a coupled thermal-structural finite element analysis of a large concrete gravity dam in Bulgaria for exploring the dam response under different actual load combinations. The loads applied to the structure are caused by varying water level in the reservoir and ambient temperature typical for the respective seasons. The developed computational model was calibrated with real plumb measurements. Based on the performed analyses in the ANSYS environment, key limit values for the horizontal displacements measured by the plumbs in the dam as possibly caused by extreme combinations of ambient temperature and water level are formulated for further improvement of the dam operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.