Abstract

Formulas that give absorbed dose buildup factors for two-layered shields have been developed based on gamma-ray absorption buildup factors computed with the Monte Carlo Neutral Particle Transport Code System (MCNP). The shielding materials considered were water, lead, steel, concrete, and some of their combinations for two-layered shields with thicknesses between 1 to 10 mfp. Gamma energy considered ranged from 0.5 to 6 MeV. The formulas reproduce MCNP results with a difference of <10%, in most cases <3%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.