Fifteen carbonyl compounds were investigated in the living rooms and bedrooms of 25 university student flats in the urban area of Ciudad Real (Central Southern Spain) in wintertime. Carbonyls were sampled using Radiello ® passive samplers refilled in the laboratory according to the method described in ISO 16000-3 Standard. The most abundant carbonyls in the living rooms and bedrooms were formaldehyde, acetone, acetaldehyde, hexaldehyde and butyraldehyde. The median concentration levels in the living rooms and bedrooms were: 28.6 and 34.2 μg m−3 for formaldehyde, 18.3 and 23.1 μg m−3 for acetone, 14.3 and 15.8 μg m−3 for acetaldehyde, 11.4 and 14.1 μg m−3 for hexaldehyde and 10.8 and 12.4 μg m−3 for butyraldehyde. The median concentration of formaldehyde, benzaldehyde, valeraldehyde and hexaldehyde was significantly higher in the bedrooms than in the living rooms. Indoor concentrations were significantly higher than outdoor concentrations for all carbonyl measured, indicating that sources in the indoor environment are prevailing in all flats. Principal component analysis, multiple linear regressions and Spearman correlation coefficients were used to investigate the origin, the indoor pollutants determinants and to establish common sources between carbonyls.Eight components were extracted from the application of PCA to the indoor and outdoor measurements accounting for 97.7% of the total variance. Formaldehyde, acetone, acetaldehyde and acrolein presented different indoor sources. In the multiple linear regression analysis, higher formaldehyde concentrations were found in those living rooms with wood floor and smoking was positively associated to acetone, propionaldehyde, benzaldehyde and isovaleraldehyde. Formaldehyde, acetaldehyde, acrolein, acetone, propionaldehyde and benzaldehyde concentrations were compared with relevant international guidelines, being their concentrations below recommended values except acrolein, where all measured flats exceeded the reference levels; it would be important to focus on the characterization of emission sources of acrolein in indoor air in order to minimise the exposure and health risk.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.