Abstract

In a recent study, we proposed a novel method to evaluate hypoxic ischemic encephalopathy (HIE) by assessing propofol-induced changes in the 19-channel electroencephalogram (EEG). The study suggested that patients with HIE are unable to generate EEG slow waves during propofol anesthesia 48 h after cardiac arrest (CA). Since a low number of electrodes would make the method clinically more practical, we now investigated whether our results received with a full EEG cap could be reproduced using only forehead electrodes. Experimental data from comatose post-CA patients (N = 10) were used. EEG was recorded approximately 48 h after CA using 19-channel EEG cap during a controlled propofol exposure. The slow wave activity was calculated separately for all electrodes and four forehead electrodes (Fp1, Fp2, F7, and F8) by determining the low-frequency (< 1 Hz) power of the EEG. HIE was defined by following the patients’ recovery for six months. In patients without HIE (N = 6), propofol substantially increased (244 ± 91%, mean ± SD) the slow wave activity in forehead electrodes, whereas the patients with HIE (N = 4) were unable to produce such activity. The results received with forehead electrodes were similar to those of the full EEG cap. With the experimental pilot study data, the forehead electrodes were as capable as the full EEG cap in capturing the effect of HIE on propofol-induced slow wave activity. The finding offers potential in developing a clinically practical method for the early detection of HIE.

Highlights

  • A substantial portion of comatose patients admitted to intensive care following successful resuscitation after cardiac arrest (CA) suffers from hypoxic ischemic encephalopathy (HIE) [1]

  • We investigated whether the slow wave activity during propofol anesthesia after CA, previously shown to differentiate patients with a good and with a poor outcome, could be detected using only forehead electrodes instead of the full 19-channel EEG cap

  • The activity decreased as the infusion rate decreased. While this phenomenon was seen in all channels, the activity was emphasized in the frontal channels, which had higher average slow wave activity throughout the experiment compared to the global average calculated over the all 19 channels

Read more

Summary

Introduction

A substantial portion of comatose patients admitted to intensive care following successful resuscitation after cardiac arrest (CA) suffers from hypoxic ischemic encephalopathy (HIE) [1]. While known to hold prognostic information in HIE for decades, the recent progress in measurement devices, including improved wireless and computational properties, has made electroencephalogram (EEG) possibly the most promising clinical tool for the assessment of brain function after CA. This is supported by the findings indicating the usefulness of simplified EEGderived parameters in the early detection of HIE [4,5,6]

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.