Abstract
The application of the folded pendulum (FP) as a tiltmeter is proposed and some features of it have been studied both theoretically and experimentally. First, FP could have a quite low resonance frequency due to its mechanical structure. The period of our prototype FP is 6.2 s and the amplification factor is about 100. Second, FP is not sensitive to the environmental temperature variation but seriously affected by the temperature gradient. The experiment with a temperature gradient modulation shows that the static equilibrium position of the FP will change by 2.5 μrad if the temperature difference between the horizontal platform and the base of the FP is 0.1 °C. With a prototype FP, we have observed obvious tilt tides, and the calibration result shows that the resolution of the FP is about 1.2 nrad.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.