In light field microscopy (LFM), the F-number of the micro lens array (MLA) should be matched with the image-side F-number of the objective lens to utilize full resolution of an image sensor. We propose a new F-number matching method that can be applied to multiple objective lenses by using an elastic MLA. We fabricate an elastic MLA with polydimethylsiloxane (PDMS) using a micro contact printing method and address the strain for the F-number variation. The strain response is analyzed, and the LFM system with the elastic MLA is demonstrated. Our proposed system can increase the F-number up to 27.3% and can be applied to multiple objective lenses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.