Abstract

The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fast neutron fluxes were found to be 2.960 × 106 and 6.186 × 107 n/cm2 s, respectively. This was done to verify the modeling results for the optimum moderator thickness needed to maximize the thermal neutron flux. The optimum moderator thickness was found to be between 3.5 and 4 cm. The present data were compared with the detailed MCNP model-based calculation performed in earlier work to simulate the generator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.