Abstract

Semiconductor switches possess nonideal behavior which, in case of isolated dc-dc converters, can generate dc-voltage components which are then applied to the isolation transformer. This dc-voltage component is translated into a dc flux density component in the transformer core, increasing the risk of driving the core into saturation. In this paper, a novel noninvasive flux density measurement principle, called “The Magnetic Ear,” based on sharing of magnetic path between the main and an auxiliary core is proposed. The active compensation of the transformer's dc magnetization level using this transducer is experimentally verified. Additionally, a classification of the previously reported magnetic flux measurement and balancing concepts is performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.