To study the flow behavior in regions where hemodynamic effects have been suggested to participate in atherogenesis, we evaluated flow in a mold of the aorta and renal arteries of a previously healthy 27-year-old woman who died of trauma. A birefringent solution (vanadium-pentoxide) was used. When diluted, this material behaves like a Newtonian fluid. This method gives a complete picture of the entire flow field. Zones of flow separation and disturbed flow can be seen and the location and size of disturbed areas observed. Unseparated flow regions downstream from disturbed zones can be properly visualized and the method can be used for pulsatile flow as well as steady flow. During steady flow (only at branch to-trunk flow ratios greater than 0.20), zones of flow separation were observed in the aorta distal to the renal arteries. During pulsatile flow, disturbances were found at nearly all branch-to-trunk flow ratios.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.