Abstract

This study investigates the impact of working clearances on the internal flow field, pressure pulsations, flow pulsations, and radial forces experienced by a hydrogen circulation pump. Numerical calculations are conducted on seven sets of distinct working clearances for the pump. The research findings demonstrate that an increase in meshing clearance and radial clearance results in higher leakage flow rate during the compression exhaust process, leading to a decrease in hydrogen circulation pump's exhaust flow rate. When the meshing clearance increases from 0.15 to 0.21 mm, the actual exhaust flow rate of the pump decreases from 37.46 to 32.73 m3 h−1. Similarly, when the radial clearance increases from 0.18 to 0.24 mm, the actual exhaust flow rate of the pump decreases from 42.46 to 29.71 m3 h−1. Additionally, with an increase in meshing clearance, both the radial forces Fx and Fy of the active rotor exhibit a downward trend. Yet, as radial clearance grows, the radial force Fx slightly descends, while the change trend of radial force Fy is first positive decrease and then reverse increase.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.